{"en":"Facades, partitions, in-situ testing. Brackets, arms and probes to put microphone and source where the standard says they go, even when the balcony disagrees.","it":"Facciate, partizioni, collaudi in opera. Staffe, bracci e sonde per mettere microfono e sorgente dove la norma dice che vadano, anche quando il balcone dice il contrario."}
The standardised angle without a balancing act on the tripod. Planned variants: tripod, pole, parapet.
It exists as a shopping list in twenty different practices, never as a product. Planned variants: studio flat, apartment, building.
Microphone 2 m off the facade, set up from indoors. Planned variants: 1 / 2 / 3 m reach — clamp or counterweight.
Spatial averaging in the receiving room without moving the tripod. Planned variants: 3, 5, 6 positions — 0.7 / 1.0 m radius.
The small elements that ruin a facade insulation index. Planned variants: 100 mm diameter, 100x300 mm rectangular.
Repeating the same measurement six months later at the same point. Planned variants: stickers, screwed tags, with QR code.
Tests on small elements (grilles, roller-shutter boxes, vents). Planned variants: 200x200, 300x300, 500x500 mm — 50/100 mm thick.
Random but traceable positions, so the report cannot be challenged. Planned variants: 5 / 10 position templates, software version.
A known surface for checking repeatability between two campaigns. Planned variants: 300x300, 500x500 mm.
Closing a gap without ruining the client's window frame. Planned variants: 1 kg sealant, 50 mm x 10 m acoustic tape, magnetic seals.
The T20 that normalisation needs, in a single container. Planned variants: base, with compact omnidirectional source, with clapper.
Volume and surfaces documented the way the report requires. Planned variants: distance meter plus template plus form, version with digital export.
Continuous spatial averaging, required by some procedures. Planned variants: 0.7 / 1.0 / 1.5 m radius — 32 s / 64 s per revolution.
Mandatory boundary conditions, written down by hand today. Planned variants: single, transmitting/receiving pair, pole-mounted version.
A repeatable position 2 m off the facade, with the height read off a scale. Planned variants: 2-4 m, 3-6 m, 4-10 m — 3 / 4 / 5 sections.
Everything an apartment needs, in one case. Planned variants: studio flat, typical apartment, whole building (3 cases).
The link between draughts and a collapse in insulation. Planned variants: manometer plus nozzles, version with ultrasonic source.
Quick fixing without drilling and without asking permission. Planned variants: 20-80 mm opening, 40-140 mm, suction-cup version.